AIDA B0DM4SGNBQ

AIDA Single Pole Motion Sensor Light Switch User Manual

Model: B0DM4SGNBQ

Branda: AIDA

Réamhrá

This manual provides detailed instructions for the installation, operation, and maintenance of your AIDA Single Pole Motion Sensor Light Switch. This device is designed to enhance convenience and energy efficiency by automatically controlling lighting based on occupancy. Please read this manual thoroughly before installation and use to ensure proper function and safety.

AIDA Single Pole Motion Sensor Light Switch and its packaging

Image: The AIDA Single Pole Motion Sensor Light Switch shown alongside its product packaging, highlighting its design and key features.

Eolas Tábhachtach Sábháilteachta

WARNING: RISK OF ELECTRIC SHOCK. Improper installation can be dangerous or illegal. Always consult a qualified electrician if you are unsure about any part of the installation process.

  • Múch an chumhacht: Always disconnect power at the circuit breaker or fuse box before installing or servicing the switch.
  • Sreang Neodrach ag Teastáil: This device requires a neutral wire for proper operation. If your electrical box does not have a neutral wire, this switch is not compatible.
  • Single Pole Only: This switch is designed for single-pole control only and is not suitable for 3-way or multiple-way circuits.
  • UL/CUL Certified: The switch is UL and CUL listed, ensuring compliance with safety standards.
  • Vol Oibriúcháintage: Ensure your electrical system operates at 120 Volts (AC).

Ábhar an Phacáiste

Deimhnigh go bhfuil na comhpháirteanna uile i láthair sula dtosaíonn tú ar an suiteáil:

  • AIDA Single Pole Occupancy Motion Sensor Light Switch
  • Pláta Balla Screwless
  • Wire Nuts (Terminal caps)
  • Scriúnna Gléasta
  • Lámhleabhar Treoracha (an doiciméad seo)

Sonraíochtaí Táirge

Gné Sonraigh
Rátáil Ionchuir 120/277V ~ 50/60Hz
Applicable Load Types 200W LED/CFL, 500W MLV, 500W INC/HAL, 5A Ballast (120V), 1/6HP Fan (4.4A 120V)
Athraigh Cineál Cuaille aonair
Tomhsaire Sreang #14 - #12 AWG
Cineál Sreangaithe Caipín críochfoirt
Teocht Oibriúcháin 32°F go 104°F (0°C go 40°C)
Méid an Táirge 4.17"x1.73"x1.77" (106x44x45mm)
Ábhar Copar, Prás (Ábhar Teagmhála)
Modh Rialaithe Sensor, Touch
Tábla toisí agus sonraíochtaí táirge

Image: A visual representation of the product dimensions and a detailed table of specifications for the AIDA motion sensor switch.

Universal compatibility chart for AIDA motion sensor switch

Image: A chart illustrating the universal compatibility of the AIDA motion sensor switch with various load types including LED/CFL, MLV, INV/HAL, Ballast, and Fan.

Socrú agus Suiteáil

Sula dTosaíonn Tú:

  1. Múch an chumhacht: Locate your circuit breaker panel and turn off the power to the switch box you will be working on. Verify power is off using a voltage tástálaí.
  2. Aithin sreanga: Carefully remove the existing wall plate and switch. Identify the following wires:
    • Line Wire (Black): Carries power from the circuit breaker.
    • Load Wire (Black): Iompraíonn cumhacht chuig an daingneán solais.
    • Sreang Neodrach (Bán): Required for this switch.
    • Sreang Talún (Copar Glas nó Nocht): For safety.
  3. Confirm Neutral Wire: This switch requires a neutral wire. If you do not have a neutral wire (typically white) in your electrical box, this switch is not compatible.

Treoracha Sreangaithe:

Follow the wiring diagram carefully. Use the provided wire nuts to secure connections.

Wiring diagram for AIDA motion sensor light switch

Image: A detailed wiring diagram showing connections for the AIDA motion sensor light switch, including Line, Load, Neutral, and Ground wires. It explicitly states that a neutral wire is required and the switch is not suitable for 3-way or multiple-way circuits.

  • Ceangail an GLAS wire from the switch to your house's TALAMH sreang.
  • Ceangail an BÁN wire from the switch to your house's NEACHTÚRACH sreang.
  • Ceangail an DUBH wire from the switch to your house's LÍNE sreang (te).
  • Ceangail an DEARG wire from the switch to your house's Ualach wire (to the light fixture).

Important: Ensure all connections are secure and insulated with wire nuts. This switch is for single-pole applications only. Do not use in 3-way or multi-way circuits.

Suiteáil an lasc:

  1. Carefully fold the wires and push the switch into the electrical box.
  2. Secure the switch to the electrical box using the provided screws.
  3. Attach the screwless wall plate.
  4. Athchóirigh an chumhacht ag an scoradán ciorcaid.
Dimensions of the AIDA motion sensor light switch and wall plate

Image: A diagram showing the precise dimensions of the AIDA motion sensor light switch, its mounting bracket, and the screwless wall plate for easy installation.

Operating Instructions and Customization

The AIDA motion sensor switch offers various modes and adjustable settings to suit your needs.

Modhanna Oibriúcháin:

  • Occupancy Mode (Auto-On/Auto-Off): Lights automatically turn ON when motion is detected and OFF after a set delay when no motion is detected. Ideal for high-traffic areas like bathrooms, laundry rooms, and kitchens.
  • Vacancy Mode (Manual-On/Auto-Off): Lights must be manually turned ON, but will automatically turn OFF after a set delay when no motion is detected. Suitable for bedrooms or TV rooms where you prefer manual control for turning on lights.

Socruithe Inchoigeartaithe:

The switch features internal dip switches for customizing settings. Carefully remove the faceplate to access these controls.

Adjustable settings for AIDA motion sensor switch

Íomhá: Dlúthghraf view of the AIDA motion sensor switch's internal settings, showing dip switches for Adjustable Light Level (Timeout), PIR Sensitivity, and Ambient Light Sensor Mode.

  • Adjustable Light Level (Timeout): This setting determines how long the light stays on after the last detected motion. Options typically include 30 seconds, 1 minute, 5 minutes, 15 minutes, or 30 minutes. Refer to the switch's internal labels for specific settings.
  • Íogaireacht PIR: Adjusts the sensitivity of the Passive Infrared (PIR) sensor to detect motion. Settings range from Low (L) to High (H). A higher sensitivity detects smaller movements or movements at a greater distance.
  • Ambient Light Sensor Mode: Controls how the switch reacts to ambient light.
    • Íseal/Ard: The switch will only turn on lights if the ambient light level is below a certain threshold (e.g., only turn on at night).
    • As: The ambient light sensor is disabled, and the switch will turn on lights regardless of ambient light.
    • Saincheaptha: Allows for more specific ambient light level adjustments.

Note: After adjusting any internal settings, reattach the faceplate securely.

mionsonraithe view of AIDA motion sensor switch internal settings

Íomhá: Mionsonraithe view of the AIDA motion sensor switch with its cover removed, showing the dip switches for adjusting timeout, PIR sensitivity, and ambient light sensor mode.

Cothabháil

The AIDA Motion Sensor Light Switch is designed for long-lasting, maintenance-free operation. To ensure optimal performance:

  • Glanadh: Periodically wipe the switch and wall plate with a soft, damp éadach. Ná húsáid glantóirí scríobacha ná tuaslagóirí, mar is féidir leo damáiste a dhéanamh don chríoch nó do na comhpháirteanna inmheánacha.
  • Bac: Ensure the sensor lens is not obstructed by furniture, decorations, or other objects, as this can impair motion detection.
  • Uimh Páirteanna Inseirbhíse Úsáideoir: There are no user-serviceable parts inside the switch. Do not attempt to open or repair the unit beyond adjusting the dip switches.

Fabhtcheartú

Fadhb Cúis Féideartha Réiteach
Light does not turn ON with motion.
  • Tá an chumhacht múchta.
  • Sreangú mícheart.
  • PIR sensitivity set too low.
  • Ambient light sensor preventing activation.
  • Obstruction blocking sensor.
  • Seiceáil an scoradán ciorcaid.
  • Verify wiring according to diagram (ensure neutral wire is connected).
  • Increase PIR sensitivity.
  • Adjust Ambient Light Sensor Mode or set to "Off" for testing.
  • Glan aon bhacainní ón braiteoir view.
Light stays ON constantly.
  • Gluaiseacht leanúnach braite.
  • Switch set to Manual ON mode (if applicable).
  • Lasc lochtach.
  • Ensure no continuous motion in the detection area.
  • Check operating mode settings.
  • Má leanann an fhadhb, déan teagmháil le tacaíocht do chustaiméirí.
Light turns OFF too quickly or too slowly.
  • Timeout setting needs adjustment.
  • Adjust the "Adjustable Light Level (Timeout)" setting using the internal dip switches.
Switch makes a clicking noise.
  • Normal operation of the internal relay.
  • This is a normal operational sound and does not indicate a fault.

Barántas agus Tacaíocht do Chustaiméirí

AIDA products are manufactured to high-quality standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty card included with your purchase or visit the official AIDA websuíomh.

If you encounter any issues or have questions regarding your AIDA Single Pole Motion Sensor Light Switch, please contact our customer support team:

  • Websuíomh: Visit the AIDA Store on Amazon (le haghaidh faisnéise ginearálta faoin táirge)
  • Ríomhphost: Féach ar phacáistiú an táirge nó ar an suíomh oifigiúil websuíomh gréasáin le haghaidh ríomhphoist teagmhála.
  • Fón: Féach ar phacáistiú an táirge nó ar an suíomh oifigiúil webSuíomh gréasáin le haghaidh uimhir theileafóin teagmhála.

Please have your model number (B0DM4SGNBQ) and purchase date ready when contacting support.

Doiciméid Ghaolmhara - B0DM4SGNBQ

Réamhview Lámhleabhar Úsáideora Ceamara AIDA HD-NDI-200 Full-HD NDI|HX2 POV
Lámhleabhar úsáideora don Cheamara POV AIDA HD-NDI-200 Full-HD NDI|HX2. Clúdaíonn sé sábháilteacht, pacáil, buaicphointí, sonraíochtaí teicniúla, OSD agus web socruithe comhéadain, prótacail VISCA agus NDI, agus faisnéis bharántais.
Réamhview Treoir Oibriúcháin don Cheamara AIDA HD-100 HD HDMI POV
Soláthraíonn an treoir oibriúcháin seo treoracha mionsonraithe don Cheamara AIDA HD-100 HD HDMI POV, lena n-áirítear gnéithe, socruithe roghchláir OSD, rialuithe íomhá, agus sonraíochtaí.
Réamhview Treoir Suiteála agus Oibriúcháin do Chloigín Doras Gan Sreang Aida
Treoir chuimsitheach maidir le Clog Doras Gan Sreang Aida a shuiteáil, a phéireáil agus a oibriú. I measc na ngnéithe tá 32 fonn, raon 150m, 5 leibhéal toirte agus brú cloig uiscedhíonach.
Réamhview AIDA GEN3G-200: 3G-SDI/HDMI FULL HD Gen-lock Camera Operation Guide
Comprehensive operation guide for the AIDA GEN3G-200, a 3G-SDI/HDMI FULL HD Gen-lock camera. Covers features, menu operations, specifications, and safety precautions.
Réamhview Lámhleabhar Ceamara PTZ Súmáil Optúil Lán-HD AIDA - PTZ-X12-IP, PTZ-NDI-X12, PTZ-X20-IP, PTZ-NDI-X20
Lámhleabhar úsáideora cuimsitheach do cheamaraí PTZ Súmáil Optúil Lán-HD AIDA (PTZ-X12-IP, PTZ-NDI-X12, PTZ-X20-IP, PTZ-NDI-X20). Clúdaíonn sé sábháilteacht, socrú, buaicphointí táirge, sonraíochtaí, comhéadan, rialú cianda, roghchlár OSD, web socruithe, prótacail VISCA (IP agus RS-232), rialú UVC, agus faisnéis bharántais.
Réamhview Telkonet Aida Thermostat: Installation, Operation, and Maintenance Guide
This guide provides detailed instructions for the installation, operation, and maintenance of the Telkonet Aida smart thermostat. It covers product features, installation procedures for high and low voltage systems, wiring diagrams, user interface explanations, and compliance information.