ACiQ ACiQ-24-AC / ACIQ-24-ACL

Lámhleabhar Úsáideora d'Aerchóiriú Inbhéartóra & Córas Corna Galaitheora ACiQ 16.5 SEER2

Model: ACiQ-24-AC / ACIQ-24-ACL | Brand: ACiQ

1. Réamhrá

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ High Efficiency 16.5 SEER2 24,000 Cooling BTU Inverter Air Conditioner and Multi-Positional Cased Evaporator Coil System. Please read this manual thoroughly before installation or operation and keep it for future reference.

The ACiQ system is designed to provide optimal cooling performance with advanced inverter technology, ensuring consistent temperature control and energy efficiency. This system includes an outdoor inverter unit, a multi-positional cased evaporator coil, and a smart thermostat for convenient control.

2. Eolas Tábhachtach Sábháilteachta

RABHADH: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Refer to this manual. For assistance or additional information, consult a qualified installer or service agency.

3. Ábhar Pacáiste

Verify that all components are present and undamaged upon receipt:

ACiQ Inverter Air Conditioner and Evaporator Coil System with Smart Thermostat

Fíor 3.1: Os a chionnview of the ACiQ Inverter Air Conditioner and Evaporator Coil System, including the outdoor unit, cased evaporator coil, and smart thermostat.

4. Socrú agus Suiteáil

Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician to ensure proper function, safety, and warranty validity.

4.1 Unit Placement and Dimensions

Ensure adequate clearance around both the outdoor and indoor units for proper airflow and maintenance access. Refer to the following dimensions for planning:

Diagram showing measurements of ACiQ outdoor unit and evaporator coil

Figure 4.1: Detailed measurements for the ACiQ outdoor unit and evaporator coil, indicating dimensions for installation planning.

4.2 Evaporator Coil Installation

The cased multi-positional evaporator coil is designed for versatile installation in various configurations. It is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

Evaporator coil with specifications for air flow, pressure, and dimensions

Figure 4.2: Specifications for the ACiQ evaporator coil, including air flow, pressure, and physical dimensions.

4.3 Naisc Leictreacha

The system requires a 208-230 voltage, 1-Phase, 60Hz electrical supply. All electrical wiring must comply with local and national electrical codes. Ensure proper circuit breaker sizing and wiring gauge for the unit's power requirements.

4.4 Píobáil Cuisneáin

This system uses R 410A refrigerant. Proper evacuation and charging procedures are critical for system performance and longevity. This process must be performed by a licensed HVAC technician.

5. Treoracha Oibriúcháin

Your ACiQ system is controlled by the included Cielo Smart Thermostat, designed for user convenience and energy efficiency.

5.1 Cielo Smart Thermostat Overview

The Cielo Smart Thermostat allows you to manage your cooling and heating settings efficiently. It ensures your system runs only when needed, helping to reduce energy consumption without compromising comfort.

Cielo Smart Thermostat and its mobile app interface

Figure 5.1: The Cielo Smart Thermostat, illustrating its sleek design and integration with a mobile application for remote control.

5.2 Thermostat Features and Controls

The thermostat offers various features for precise climate control and smart home integration:

Diagram of Cielo Smart Thermostat features including mode, humidity, set points, and smart home integrations

Figure 5.2: An illustrative diagram detailing the various features and control points of the Cielo Smart Thermostat, including its compatibility with popular smart home platforms.

6. Cothabháil

Regular maintenance ensures the longevity and efficiency of your ACiQ system. Always disconnect power to the unit before performing any maintenance.

6.1 Air Filter Replacement/Cleaning

Check and clean or replace the air filter in your furnace or air handler every 1-3 months, or more frequently if you have pets or allergies. A dirty filter restricts airflow and reduces efficiency.

6.2 Outdoor Unit Coil Cleaning

Periodically inspect the outdoor unit's condenser coil for dirt, leaves, and debris. Gently clean the coil with a soft brush or hose. Avoid bending the fins. Ensure the area around the outdoor unit is clear of obstructions.

Close-up of the ACiQ outdoor unit's fan and coil

Fíor 6.1: Dlúth-amharc view of the ACiQ outdoor unit, highlighting the fan and condenser coil, which require periodic cleaning for optimal performance.

6.3 Seirbhísiú Gairmiúil

It is recommended to have a qualified HVAC technician perform annual maintenance on your system. This includes checking refrigerant levels, electrical connections, and overall system performance.

7. Fabhtcheartú

Sula ndéanann tú teagmháil le tacaíocht do chustaiméirí,view na saincheisteanna coitianta seo a leanas agus a réitigh:

FadhbCúis FéidearthaRéiteach
System not cooling/heatingThermostat settings incorrect, dirty air filter, tripped circuit breaker, outdoor unit obstructed.Check thermostat mode and temperature settings. Clean/replace air filter. Reset circuit breaker. Clear obstructions around outdoor unit.
Sreabhadh aeir lagDirty air filter, blocked return air vents, duct leaks.Clean/replace air filter. Ensure vents are open and unobstructed. Inspect ducts for leaks (professional service recommended).
Fuaimeanna neamhghnáchaLoose parts, fan motor issues, refrigerant issues.Turn off unit and inspect for loose panels or debris. If noise persists, contact a qualified technician.
System cycles on and off frequentlyOversized unit, low refrigerant, dirty coils.Ensure proper sizing during installation. Check for refrigerant leaks and clean coils. Contact a technician for diagnosis.
Leak detection alertSceite cuisneáin.The system is equipped with leak detection. If an alert occurs, immediately contact a qualified HVAC technician for inspection and repair.

8. Sonraíochtaí

Key technical specifications for the ACiQ 16.5 SEER2 24,000 BTU Inverter Air Conditioner and Evaporator Coil System:

GnéSonraigh
BrandaACiQ
Ainm an tSamhailACiQ-24-AC / ACIQ-24-ACL
Cumas Fuarú24,000 BTU/h (2 Tons)
Rátáil SEER2Suas le 16.5
Foinse CumhachtaCorded Leictreach
Imltage208-230V, 1-Phase, 60Hz
Cineál CuisneáinR 410A
Toisí Aonaid Lasmuigh (W x D x H)35.04" x 13.46" x 26.5"
Evaporator Coil Dimensions (W x D x H)17.52" x 20.98" x 17.99"
Modh RialaitheRemote Control (Cielo Smart Thermostat)
AHRI Certification and EnergyGuide label for ACiQ system

Figure 8.1: AHRI Certification and EnergyGuide label, confirming the system's performance ratings and energy efficiency.

9. Barántas agus Tacaíocht

9.1 Coinníollacha Barántais

The ACiQ system comes with a Barántas páirteanna 10 bliana when installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records for warranty claims.

For detailed warranty terms and conditions, please refer to the warranty documentation included with your product or visit the official ACiQ websuíomh.

Warehouse showing packaged AC units ready for shipment

Figure 9.1: Expert packaging of ACiQ units in a warehouse, ensuring product integrity during transit.

Well-kept warehouse interior with organized product shelving

Fíor 9.2: Taobh istigh view of a well-maintained ACiQ warehouse, demonstrating careful handling and storage of products.

9.2 Tacaíocht do Chustaiméirí

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact ACiQ customer support. Contact information can typically be found on the manufacturer's weban suíomh nó ar phacáistiú an táirge.

When contacting support, please have your model number (ACiQ-24-AC / ACIQ-24-ACL) and purchase date readily available.

10. Acmhainní Breise

For further information, product updates, or to explore other ACiQ products, please visit the official ACiQ websuíomh:

Visit the ACiQ Store on Amazon

Doiciméid Ghaolmhara - ACiQ-24-AC / ACIQ-24-ACL

Réamhview Lámhleabhar Suiteála Córais Inbhéartóra Láir ACiQ
Lámhleabhar suiteála cuimsitheach do Chórais Aerchóirithe agus Caidéil Teasa Inbhéartóra Láir ACiQ, ina bhfuil sonraí faoi réamhchúraimí sábháilteachta, píopaíocht cuisneáin, suiteáil aonaid lasmuigh, sreangú, sonraíochtaí cumhachta, aslonnú aeir, agus nósanna imeachta tástála.
Réamhview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures. Includes model details and important notes for proper setup.
Réamhview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, wiring, unit installation, and testing procedures for models like ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, and others.
Réamhview Lámhleabhar Suiteála Láimhseálaí Aeir Duchtaithe ACiQ (12K-60K BTU/u)
Soláthraíonn an lámhleabhar suiteála seo ó ACiQ treoracha mionsonraithe maidir le suiteáil shábháilte agus cheart aonaid Láimhseálaí Aeir Duchtaithe, samhlacha 12K go 60K BTU/h. Clúdaíonn sé treoirlínte sábháilteachta riachtanacha, socrú aonad, píopaíocht cuisneáin, sreangú leictreach, sonraíochtaí, agus tástáil oibríochtúil chun feidhmíocht is fearr agus fad saoil an chórais a chinntiú.
Réamhview Lámhleabhar Úinéara Láimhseálaí Aeir Duchtaithe ACiQ Extreme+
Lámhleabhar cuimsitheach úinéara don Láimhseálaí Aeir Duchtaithe ACiQ Extreme+ (18K-60K), ina bhfuil réamhchúraimí sábháilteachta, páirteanna, cothabháil agus fabhtcheartú.
Réamhview Lámhleabhar Suiteála Láimhseálaí Aeir Duchtaithe ACiQ
Lámhleabhar suiteála cuimsitheach d’aonaid Láimhseálaí Aeir Duchtaithe ACiQ (12K-60K BTU/u). Clúdaíonn sé sábháilteacht, suiteáil aonaid, sreangú, píopaíocht cuisneáin, agus nósanna imeachta tástála do mhúnlaí ACiQ-12-AHD go ACiQ-60-AHD.