PRIME e2prime

PRIME 12,000 BTU Ductless Air Conditioner, Heat Pump Mini Split User Manual

Model: e2prime | Brand: PRIME

Réamhrá

Thank you for choosing the PRIME 12,000 BTU Ductless Air Conditioner and Heat Pump Mini Split system. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new unit. Please read this manual thoroughly before installation and use, and keep it for future reference.

This versatile system offers 5 modes for your comfort: Auto, Cool, Dry, Heat, and Fan. It is designed for ease of control with the included backlit LCD remote controller, ensuring optimal climate control in your space. The PRIME mini split system is engineered for energy efficiency, contributing to significant energy savings over time.

Eolas Sábháilteachta

Chun díobháil don úsáideoir nó do dhaoine eile agus damáiste maoine a chosc, caithfear na treoracha seo a leanas a leanúint. D’fhéadfadh dochar nó damáiste a bheith i gceist le hoibriú mícheart mar gheall ar neamhaird a dhéanamh ar threoracha.

Comhpháirteanna Táirge

Your PRIME Mini Split system is shipped in two separate packages and includes the following main components:

PRIME Mini Split Indoor and Outdoor Units

Image: The indoor unit (top) and outdoor unit (bottom) of the PRIME mini split air conditioner system. The indoor unit is a sleek white rectangular shape, and the outdoor unit features a protective grille over its fan and a PRIME logo.

Socrú agus Suiteáil

Installation of a ductless mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC professional to ensure proper operation, safety, and warranty validity.

Díphacáil

Carefully unpack both the indoor and outdoor units. Inspect all components for any shipping damage. Report any damage to your supplier immediately. Keep all packaging materials until the unit is fully installed and tested.

PRIME Mini Split Product Packaging

Image: Several PRIME mini split air conditioner units in their original cardboard packaging, stacked in a warehouse setting. The boxes display product information and branding.

Breithnithe Socrúcháin

Ceangal Leictreach

The unit requires a 110/120V power supply. All electrical wiring must comply with local and national electrical codes. A dedicated circuit is recommended.

Ceangal Líne Cuisneáin

The system includes a full installation accessory kit with a quick connector for the refrigerant lines. This simplifies the connection process, but proper vacuuming and leak testing are still crucial and should be performed by a professional.

Treoracha Oibriúcháin

Your PRIME mini split system is controlled via the included backlit LCD remote controller. Familiarize yourself with the remote's buttons and display for optimal use.

Cianrialtán Tharview

The remote features a clear LCD display showing current settings, temperature, and mode. Buttons are intuitively placed for easy access to various functions. Refer to the remote control's dedicated section in the full manual for a detailed button layout.

Modhanna Oibriúcháin

Coigeartú Teochta

Use the temperature up/down buttons on the remote to set your desired room temperature. The display will show the set temperature.

Rialú Luas Fan

The unit offers three fan speeds (Low, Medium, High) and an Auto-speed setting. In Auto-speed, the unit adjusts the fan speed automatically based on the operating mode and temperature difference.

Feidhm Codlata

Activate the Sleep function for energy savings and quiet operation during nighttime hours. The unit will gradually adjust the temperature and fan speed for comfortable sleep.

Automatic Air Swing

The Automatic Air Swing feature ensures even distribution of conditioned air throughout the room by automatically moving the louver. This can be toggled on or off via the remote.

PRIME Mini Split Indoor Unit with R410A Refrigerant Label

Image: The sleek white indoor unit of the PRIME mini split system, featuring a digital display showing "24" and a prominent green circular label indicating "Eco-friendly Refrigerant R410A".

Cothabháil

Regular maintenance is crucial for the efficient and long-lasting operation of your PRIME mini split system. Always disconnect power to the unit before performing any maintenance.

Glanadh Scagaire

The indoor unit is equipped with washable filters. Clean these filters every two weeks or more frequently if the unit is used heavily or in dusty environments. Dirty filters can reduce efficiency and airflow.

  1. Oscail painéal tosaigh an aonaid faoi dhíon.
  2. Bain na scagairí aeir.
  3. Wash the filters with lukewarm water and a mild detergent. Rinse thoroughly.
  4. Lig do na scagairí triomú go hiomlán in áit scáthaithe sula gcuirfidh tú ar ais iad. Ná nochtaigh do sholas díreach na gréine iad.
  5. Reinstall the dry filters and close the front panel.

Glanadh Aonaid Allamuigh

Periodically check the outdoor unit for debris, leaves, or dirt that may accumulate on the coils or fan blades. Gently clean with a soft brush or vacuum. Do not spray water directly onto electrical components.

Cothabháil Séasúrach

Before the start of each cooling or heating season, it is advisable to have a qualified technician perform a comprehensive check of the system, including refrigerant levels, electrical connections, and overall performance.

Fabhtcheartú

Before contacting customer support, please refer to the following table for common issues and their potential solutions. Many minor problems can be resolved by the user.

FadhbCúis FéidearthaRéiteach
Ní chasann aonad air.Gan soláthar cumhachta; scoradán ciorcaid imithe; cadhnraí rialaithe iargúlta marbh.Seiceáil an nasc cumhachta; athshocraigh an scoradán ciorcaid; cuir cadhnraí an chianrialtáin ina n-áit.
Fuarú/téamh neamhleor.Dirty air filters; blocked outdoor unit; wrong mode selected; low refrigerant.Clean air filters; clear obstructions from outdoor unit; select correct mode; contact professional for refrigerant check.
Torann neamhghnách ón aonad.Loose parts; fan obstruction; unit not level.Check for loose screws; remove any obstructions; ensure unit is level. If noise persists, contact service.
Uisce ag sceitheadh ​​ón aonad faoi dhíon.Clogged drain pipe; improper installation.Check and clear drain pipe; contact professional for inspection.

Sonraíochtaí Teicniúla

GnéSonraíocht
Ainm an BhrandaPRIME (Generic)
Model Info / Item Model Numbere2prime
Uimhir Pháirt502259-444237
Cumas Fuarú12,000 BTU
Imltage110/120 Volta
Cóimheas Éifeachtúlachta Fuinnimh Séasúrach (SEER)12.6 (as per feature bullets) / 12.2 (as per specifications)
Leibhéal Torainn32 dB
Meáchan Mír22 pounds (likely indoor unit only, total weight is higher for two packages)
Capacity (Air Volume)550 troigh chiúbach
Tomhaltas Bliantúil Fuinnimh2800 Cileavata Uair sa Bhliain
Cineál SuiteáilCóras Scoilte
Fachtóir FoirmeMini-Scoilt
Gnéithe SpeisialtaHeating And Cooling Function, Sleep Function, Automatic Air Swing, Washable Filters
DathBán
Comhpháirteanna San áireamhIndoor Unit, Outdoor Unit, Full installation accessory kit with quick connector
Achar Urláir MoltaSuas le 600 troigh cearnach
Cable Length (Refrigerant Line)13 troigh
Toisí an Táirge (Aonad Laistigh)7"D x 30"W x 10"H
Rátáil Réalta BEE5 réalta

Faisnéis Bharántas

The PRIME Mini Split system comes with a limited warranty. Specific warranty terms, including coverage duration for parts and compressor, are typically provided with the product documentation or can be obtained from your point of purchase. Please retain your proof of purchase for warranty claims.

Note: Improper installation or unauthorized servicing may void the product warranty.

Tacaíocht do Chustaiméirí

If you encounter issues that cannot be resolved using the troubleshooting guide, or if you require technical assistance or parts, please contact your retailer or the manufacturer's customer support. Have your model number (e2prime) and purchase date ready when contacting support.

For the most up-to-date contact information, please refer to the packaging or the official product websuíomh.

Doiciméid Ghaolmhara - e2prime

Réamhview PRIME-750B Power Supply Unit: Quick Start Guide and Safety Information
Comprehensive guide for the PRIME-750B power supply unit, covering essential safety information, installation steps, component connection, powering up instructions, and technical specifications. Includes details on electrical safety, ventilation, hardware compatibility, and protection features.
Réamhview Lámhleabhar Úinéara Solas Oibre LED Ultra-Chaol In-athluchtaithe PRIME LEDWLRHH02
Lámhleabhar úinéara don solas oibre LED ultra-chaol in-athluchtaithe PRIME LEDWLRHH02. Soláthraíonn sé treoracha maidir le tosú, oibriú, glanadh, cothabháil, fabhtcheartú, agus faisnéis bharántais.
Réamhview Lámhleabhar Úsáideora PRIME SmartOutlets - Breiseáin Chliste Rialaithe Cianrialaithe Allamuigh
Lámhleabhar úsáideora cuimsitheach do PRIME SmartOutlets, ina bhfuil sonraí faoi thus, suiteáil, sábháilteacht, barántas, agus fabhtcheartú do phlocóidí cliste lasmuigh atá rialaithe go cianda. Foghlaim conas ceangal le Wi-Fi, Cúntóir Google, Alexa, agus Siri.
Réamhview PRIME EZ-SET 24-HOUR DIGITAL TIMER (Model #TNIDEZ1) - Instruction Manual
Instruction manual for the PRIME EZ-SET 24-HOUR DIGITAL TIMER (Model #TNIDEZ1), covering programming, features, troubleshooting, safety, specifications, and warranty information.
Réamhview Prime EZ-Set Indoor Digital Timer Model TNIDP12 User Manual
User manual and specifications for the Prime EZ-Set Indoor Digital Timer, Model TNIDP12. Includes programming instructions, safety information, FCC/IC regulatory statements, and a limited 1-year warranty.
Réamhview PRIME 2 Outlet Wall Tap with USB Chargers - User Guide and Warranty
Detailed instructions, regulatory information, and warranty details for the PRIME 2 Outlet Wall Tap with USB Chargers (Model USB05) from Prime Wire & Cable, Inc.