Model: SUNDCCB160MC2P

1. Táirge Tharview

The Suntree DC Molded Case Circuit Breaker is engineered to safeguard DC electrical installations from overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms for reliable protection. Upon detecting a fault, the circuit breaker automatically interrupts the electrical circuit, preventing wire damage and reducing fire risk. This device can also be manually opened under its full rated load for electrical maintenance without sustaining damage. Designed for reversible connection, the circuit breaker can be wired in either direction and supports bidirectional current flow. Clear markings on the handle indicate the contact position (ON/OFF) at a glance. Its design facilitates easy installation on both standard DIN rails and vertical surfaces.

Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

Figure 1: Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

2. Faisnéis Sábháilteachta

  • Always disconnect power before installing or servicing the circuit breaker.
  • Installation should be performed by qualified personnel in accordance with local electrical codes and standards.
  • Ensure proper wire sizing and terminal connections to prevent overheating.
  • Ná hoibrigh an scoradán ciorcaid má tá cuma damáiste air.
  • Caith trealamh cosanta pearsanta (TCP) cuí agus tú ag obair le córais leictreacha.

3. Suiteáil

3.1 Ábhar an Phacáiste

  • 160A 2P DC Molded Case Circuit Breaker
  • Scriúnna Gléasta
  • Insulation Barrier (2 pieces)
Dimensions and included components of the circuit breaker

Figure 2: Product Dimensions and Included Components

3.2 Gléasta

The circuit breaker supports both DIN rail and vertical surface mounting. Ensure the mounting location is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.

Diagram showing quick installation on DIN rail with insulation barriers

Figure 3: Quick Installation on DIN Rail

3.3 Naisc Sreangaithe

Connect the DC positive and negative cables to the corresponding terminals on the circuit breaker. The circuit breaker is designed for reversible connection and functions with bidirectional current. Ensure all connections are secure and tight. Install the provided insulation barriers between terminals for enhanced safety.

Wiring diagram showing positive and negative connections to the circuit breaker

Fíor 4: Léaráid Nasctha

3.4 Sizing Tips for Circuit Breaker Selection

Proper sizing is crucial for effective protection.

  • For controller/inverter/DC device:
    1. Determine the maximum continuous operating current (current = watt/voltagagus).
    2. Calculate maximum current = 1.25 x maximum continuous operating current.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
  • For solar panel:
    1. Determine the short-circuit current.
    2. Calculate maximum current = Short-circuit current x 1.25 x 1.25.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
Diagram illustrating sizing tips for circuit breakers in solar systems

Figure 5: Circuit Breaker Sizing Guidelines

4. Oibríocht

4.1 Múchadh / Lasmuigh

To switch the circuit breaker ON, push the handle to the 'ON' position. To switch it OFF, push the handle to the 'OFF' position. The handle's position clearly indicates the contact status.

Image showing the ON and OFF positions of the circuit breaker handle

Figure 6: ON/OFF Markings

4.2 Protection Mechanisms

The circuit breaker provides protection against both overload and short-circuit conditions. In the event of an electrical fault, the breaker will automatically trip to protect the system.

Diagram illustrating overload and short-circuit protection features

Figure 7: Overload and Short-circuit Protection

5. Cothabháil

After the circuit breaker has tripped due to a fault, it can be reset manually. No damage occurs to the breaker itself from tripping. Regular visual inspection for any signs of wear or damage is recommended. Ensure connections remain tight.

Diagram showing mechanical and electrical life cycles, and high electrical conductivity

Figure 8: Durability and Conductivity

6. Fabhtcheartú

  • Breaker trips frequently: This indicates an overload or short circuit in the system. Identify and resolve the underlying electrical issue before resetting the breaker.
  • Breaker does not reset: Ensure the fault condition has been cleared. If the breaker still does not reset, it may be damaged and require replacement.
  • No power after installation: Verify all wiring connections are correct and secure. Check for proper input voltage and ensure the breaker is in the 'ON' position.

7. Sonraíochtaí

GnéSonraíocht
BrandaRenogy
Rátáil Reatha160 Amps
Cineál Breaker CircuitCaighdeán
Cineál GléastaSliabh Dromchla
Líon na Polannaigh2
UPC810009719694
MonaróirRenogy
Uimhir PháirtSUNDCCB160MC2P
Meáchan Mír5.15 punt
Toisí Táirge7.9 x 3.5 x 5.3 orlach
ÁbharCopar
Comhpháirteanna San áireamh160A 2P DC Molded Case Circuit Breaker, Mounting Screws, Insulation Barrier

8. Barántas agus Tacaíocht

Renogy offers a 1-year material and workmanship warranty for this product. For technical support or warranty claims, please visit the official Renogy websuíomh nó déan teagmháil lena seirbhís do chustaiméirí.

Le haghaidh tuilleadh eolais, tabhair cuairt ar an Renogy Store.

Doiciméid Ghaolmhara - SUNDCCB160MC2P

Réamhview Lámhleabhar Ginearálta Trealamh Gréine Lasmuigh den Ghreille Renogy: Treoir Suiteála agus Oibriúcháin
Soláthraíonn an lámhleabhar seo treoracha cuimsitheacha maidir le suiteáil, sreangú agus cothabháil an Trealamh Gréine Lasmuigh den Ghreille Renogy. Foghlaim faoi réamhchúraimí sábháilteachta, córais gléasta, cumraíochtaí ceallraí, agus naisc chórais le haghaidh cumhacht iontaofa lasmuigh den ghreille.
Réamhview Lámhleabhar Úsáideora Trealamh Gréine Lasmuigh den Ghreille Renogy: Treoir Suiteála, Sreangaithe agus Gléasta
Lámhleabhar úsáideora cuimsitheach do Threalamh Gréine Lasmuigh den Ghreille Renogy, a chlúdaíonn suiteáil, sreangú, córais gléasta (Lúibín Z, Iarnród, Cuaille), cumraíochtaí ceallraí, réamhchúraimí sábháilteachta, agus úsáid fiús ANL do RVanna, báid, agus córais chumhachta lasmuigh den ghreille.
Réamhview Renogy battery shunt 300 lámhleabhar úsáideora
Comprehensive user manual for the Renogy Battery Shunt 300, providing installation, operation, configuration, and troubleshooting guidance for intelligent battery monitoring in solar and off-grid systems.
Réamhview Treoir Thapa Renogy ONE Core | Suiteáil agus Oibriú
Treoir thapa don Renogy ONE Core (RSHGWSN-W02W-G3), a chlúdaíonn suiteáil, nascadh, agus oibriú bunúsach. Foghlaim conas do Renogy ONE Core a chur ar bun chun feidhmíocht is fearr a bhaint amach.
Réamhview Lámhleabhar Úsáideora agus Sonraíochtaí Teicniúla Modúl Bluetooth Renogy BT-2
Treoir chuimsitheach don Mhodúl Bluetooth Renogy BT-2, ina bhfuil sonraí faoi a ghnéithe, sainaithint na gcodanna, oibriú, sonraíochtaí teicniúla, agus nasc aip le haghaidh rialtóirí muirir gréine.
Réamhview Renogy ONE Core User Manual: Comprehensive Guide to Energy Monitoring and Smart Home Integration
This user manual provides detailed instructions for the Renogy ONE Core, covering installation, operation, features like RV leveling and smart home integration, troubleshooting, and technical specifications. Learn how to monitor and manage your energy systems effectively.