1. Réamhrá
This manual provides essential information for the proper installation, operation, and maintenance of your Klimaire KSIR036H218 3 Ton Light Commercial Floor/Ceiling Inverter Heat Pump System. Please read this manual thoroughly before using the unit and retain it for future reference. Proper understanding and adherence to these instructions will ensure optimal performance and longevity of your system.
2. Faisnéis Sábháilteachta
Important: Installation and service of this equipment must be performed by a licensed HVAC technician. Improper installation or service can result in electric shock, fire, property damage, personal injury, or death.
- Dícheangail an chumhacht ón aonad i gcónaí sula ndéantar aon chothabháil nó seirbhís.
- Cinntigh talamh ceart chun turraing leictreach a chosc.
- Ná déan iarracht an t-aonad a dheisiú nó a mhodhnú tú féin. Déan teagmháil le teicneoir seirbhíse cáilithe.
- Coinnigh leanaí agus peataí ar shiúl ón aonad lasmuigh.
- Ensure adequate ventilation around the outdoor unit.
3. Táirge Tharview
The Klimaire KSIR036H218 is a versatile 3-ton light commercial inverter heat pump system designed for efficient heating and cooling in various commercial environments. Its flexible design allows for floor, low-wall, or ceiling suspension mounting.
Príomhghnéithe
- Inverter technology for energy efficiency and precise temperature control.
- Extremely quiet operation, suitable for heavy traffic and public areas.
- Flexible installation: ceiling, low wall, or floor mounting.
- Includes a wireless remote control for convenient operation.
- Multiple operating modes: Cooling, Heating, Fan, and Dehumidification.
- Advanced functions: 24-hour timer, sleep mode, auto restart, refrigerant leak detection.
- 3D airflow with auto swing louvers for even air distribution.
- Built-in base pan heater for reliable operation down to 5°F.
- Washable, reusable air filter for easy maintenance.
Comhpháirteanna san áireamh
- Indoor Floor/Ceiling Unit
- Aonad Comhdhlúthadáin Allamuigh
- Cianrialú Gan Sreang
- Lúibín Wall
- 15-ft Installation Kit (refrigerant piping, electrical wiring, drain hose, insulation)
Amhairc Táirge




4. Socrú agus Suiteáil
Warning: This system requires professional installation by a licensed HVAC technician. Attempting to install this unit without proper qualifications can void the warranty and lead to serious hazards.
- Roghnú Suímh: Choose an installation location that allows for proper airflow, drainage, and maintenance access for both indoor and outdoor units.
- Gléasta Aonaid Laistigh: The indoor unit can be mounted on the ceiling, low on a wall, or directly on the floor. Ensure the mounting surface is strong enough to support the unit's weight.
- Suíomh Aonaid Allamuigh: The outdoor condenser is pre-charged with refrigerant for up to 25 feet of piping. It can be placed on a level ground surface or mounted to a wall using the provided wall brackets.
- Píopaí Cuisneáin: Connect the pre-charged outdoor unit to the pre-vacuumed indoor unit using the provided installation kit. Ensure all connections are leak-free.
- Naisc Leictreacha: Connect the unit to a dedicated power supply according to local electrical codes. The system operates on 208-230V.
- Draenáil: Install the drain hose to ensure proper condensation removal from the indoor unit.
5. Treoracha Oibriúcháin
Your Klimaire heat pump system is controlled via the included wireless remote control. Familiarize yourself with the remote's functions for optimal use.

Feidhmeanna Cianrialaithe
- Cnaipe AR/AS: Cumhachtaíonn sé an t-aonad ar siúl nó as.
- Cnaipe MODE: Cycles through operating modes: Auto, Cool, Heat, Fan, Dry (Dehumidification).
- TEMP Buttons (Up/Down): Coigeartaíonn sé an socrú teochta atá ag teastáil.
- Cnaipe FAN: Roghnaíonn luas an luchtóra (Uathoibríoch, Íseal, Meánach, Ard).
- Cnaipe SWING: Activates or deactivates the automatic louver swing for even air distribution.
- TIMER AR / AS: Sets the automatic on/off times for the unit.
- Mód SLEEP: Adjusts temperature settings automatically during sleep for comfort and energy saving.
- Mód TURBO: Soláthraíonn sé fuarú nó téamh tapa ar feadh tréimhse ghearr.
Modhanna Oibriúcháin
- Mód Fuarú: Provides cooling to maintain the set temperature.
- Mód Téimh: Provides heating to maintain the set temperature, effective down to 5°F ambient temperature.
- Mód Fan: Scaipeann sé aer gan téamh ná fuarú.
- Mód Tirim (Dí-thaisithe): Laghdaíonn sé an taise sa seomra.
- Mód Auto: Roghnaíonn an t-aonad an modh cuí (Fuarú, Teas, nó Gaothrán) go huathoibríoch bunaithe ar theocht an tseomra agus ar an teocht atá socraithe agat.
Atosaigh Auto: In case of a power interruption, the unit will automatically restart with the previous settings once power is restored.
6. Cothabháil
Regular maintenance ensures efficient operation and extends the lifespan of your heat pump system. Always disconnect power before performing maintenance.
- Glanadh Scagaire Aeir: The indoor unit features a washable, reusable air filter. Clean the filter every 2-4 weeks, or more frequently depending on usage and air quality. Remove the filter, wash it with mild detergent and water, rinse thoroughly, and allow it to dry completely before reinserting.
- Indoor Unit Cleaning: Glan taobh amuigh an aonaid faoi dhíon le clúdach bog,amp éadach. Ná húsáid ceimiceáin gharbh ná glantóirí scríobacha.
- Glanadh Aonaid Allamuigh: Periodically clear any debris (leaves, dirt) from around the outdoor condenser unit. Ensure the coils are clean and free of obstructions. A garden hose can be used to gently rinse the coils.
- Cigireacht Ghairmiúil: It is recommended to have a licensed HVAC technician perform an annual inspection and professional cleaning to ensure all components are functioning correctly and to check refrigerant levels.
7. Fabhtcheartú
Sula ndéanann tú teagmháil leis an tseirbhís,view the following common issues and solutions. If the problem persists, contact a licensed HVAC technician.
| Fadhb | Cúis Féideartha | Réiteach |
|---|---|---|
| Ní chuireann an t-aonad ar siúl | No power supply; Remote control batteries low; Circuit breaker tripped | Check power connection; Replace remote batteries; Reset circuit breaker |
| Fuarú/téamh neamhleor | Dirty air filter; Blocked outdoor unit; Incorrect mode setting; Low refrigerant | Clean air filter; Clear obstructions from outdoor unit; Select correct mode; Contact technician for refrigerant check |
| Fuaimeanna neamhghnácha | Loose parts; Fan obstruction; Refrigerant flow noise (normal) | Check for loose panels; Clear obstructions; Consult technician if noise is excessive or unusual |
| Sceitheadh uisce ón aonad faoi dhíon | Píobán draenála blocáilte; Suiteáil mhíchuí | Check and clear drain hose; Contact technician for inspection |
8. Sonraíochtaí Teicniúla
Below are the key technical specifications for the Klimaire KSIR036H218 system.
| Sonraíocht | Luach |
|---|---|
| Branda | Klimaire |
| Uimhir Mhúnla | KSIR036H218 |
| Cumas | 3 Thonna (36,000 BTU) |
| Cóimheas Éifeachtúlachta Fuinnimh Séasúrach (SEER) | 16.00 |
| Heating Seasonal Performance Factor (HSPF) | 10.00 - 10.50 |
| Imltage | 230 Volta |
| Leibhéal Torainn (Aonad Lasmuigh) | 54 Deicibeil |
| Cineál Suiteáil | Split System (Floor/Ceiling) |
| Gnéithe Speisialta | 5°F Low ambient Heating and Cooling operation, Adjustable airflow with wireless LED remote, Auto restart after power failure, Auto swing louvers, Timer Option |
| Comhpháirteanna San áireamh | Indoor Floor/Ceiling Unit, Outdoor Condenser, Wall Bracket, 15-ft Installation Kit |

9. Barántas agus Tacaíocht
Your Klimaire heat pump system is backed by a manufacturer's warranty.
- Barántas Comhbhrúiteora: The system includes a 5-Year Compressor Manufacturer Warranty.
- General Support: For warranty claims, technical assistance, or service inquiries, please contact Klimaire customer support or an authorized Klimaire service center. Ensure you have your model number (KSIR036H218) and proof of purchase available.
- Seirbhís Ghairmiúil: All service and repairs should be conducted by a licensed HVAC professional to maintain warranty validity and ensure safe operation.