The GoControl GC-TBZ48 Z-Wave Battery-Powered Smart Thermostat offers advanced control over your home's heating and cooling system. It is designed for easy installation and integrates seamlessly with Z-Wave hubs, providing remote access and smart automation capabilities. This thermostat can be powered by four AA batteries or an HVAC system's 24-volt AC C-wire.

Fíor 1: Tosaigh view of the GoControl Smart Thermostat, showing the LCD display and control buttons.
Príomhghnéithe
- Z-Wave Compatibility: Works with most Z-Wave hubs, including 2GIG GC2 panel.
- Roghanna Déchumhachta: Can be powered by 4 AA batteries (up to 2 years) or a 24-volt AC C-wire.
- HVAC System Support: Compatible with standard HVAC systems (2-stage heat & 2-stage cool) and heat pump HVAC systems (3-stage heat & 2-stage cool).
- Ríomhchlárú Éasca: Features a 7-character scrolling display for simplified programming.
- Rialú Gutha: Works with Alexa for voice control (hub and Alexa device sold separately).
- FLiRS Functionality: Supports Z-Wave FLiRS (Frequently Listening Routing Slave) for improved responsiveness.
- Firmware Upgradable: USB firmware upgrade capability.
Suiteáil agus Socrú
1. Réamhchúraimí Sábháilteachta
- Always turn off power to the HVAC system at the circuit breaker before installation.
- Ensure all wiring is performed by a qualified individual if you are unsure.
- Lean gach cód áitiúil leictreach.
2. Gléasadh an Teirmeastait
The thermostat can be wall-mounted or installed on a single-gang junction box. Choose a location away from direct sunlight, drafts, and heat sources for accurate temperature readings.
3. Treoracha Sreangaithe
The GC-TBZ48 supports both battery power and 24V AC C-wire power. Refer to the wiring diagrams below for common HVAC system configurations. Ensure wires are securely connected to the appropriate terminals.
- Standard HVAC Systems: Connect R, W, Y, G, C (if using C-wire).
- Heat Pump Systems: Connect R, O/B, Y, G, C (if using C-wire), W2/Aux.
Note: Detailed wiring diagrams are typically found in the full PDF user guide. For specific wiring, consult the document linked in the product information.
The product description mentions a user guide PDF: Treoir Úsáideora (PDF)
4. Suiteáil Battery
If not using the C-wire, install four AA alkaline batteries into the front-loading battery compartment. Ensure correct polarity. The thermostat is designed to operate for up to 2 years on battery power.
5. Z-Wave Pairing
- Put your Z-Wave hub into inclusion/pairing mode.
- On the thermostat, navigate to the menu and select "Install" or "Pair".
- The thermostat will display a confirmation once successfully paired.
- Configure the thermostat mode (e.g., "Heat-pump" mode) via the thermostat menu or your Z-Wave controller as needed.
Oibriú an Teirmeastat
Rialuithe Láimhe
- Cnaipe MODE: Cycles through system operating modes: Off, Heat, Cool, Auto.
- Cnaipe FAN: Cycles through fan operation modes: Auto (fan runs only when heating/cooling) or On (fan runs continuously).
- Saigheada Suas/Síos: Adjusts the temperature setpoint.
Rialú Z-Tonn
Once paired with a Z-Wave hub, you can control the thermostat remotely via your hub's interface or associated mobile application. This includes:
- Changing system mode (Heat, Cool, Auto, Off).
- Adjusting temperature setpoints.
- Setting fan mode.
- Creating schedules and automation rules (functionality depends on your Z-Wave hub).
Cothabháil
- Athsholáthar Ceallra: Replace AA batteries approximately every 2 years, or when the low battery indicator appears on the display. Use high-quality alkaline batteries.
- Glanadh: Glan taobh amuigh an teirmeastait le clúdach bog,amp éadach. Ná húsáid glantóirí nó tuaslagóirí scríobach.
- Nuashonruithe Firmware: Check the GoControl website or your Z-Wave hub manufacturer's support pages for available firmware updates. The thermostat supports USB firmware upgrades.
Fabhtcheartú
| Fadhb | Cúis Féideartha | Réiteach |
|---|---|---|
| Thermostat not powering on. | Dead batteries or no C-wire connection. | Replace batteries or verify C-wire connection and HVAC power. |
| Cannot pair with Z-Wave hub. | Hub not in inclusion mode, thermostat too far from hub, or interference. | Ensure hub is in inclusion mode. Move thermostat closer to hub. Check for Z-Wave network interference. Try excluding and re-including the device. |
| HVAC system not responding. | Incorrect wiring, HVAC power off, or thermostat mode incorrect. | Verify wiring connections. Check HVAC system's circuit breaker. Ensure thermostat is set to the correct system mode (Heat/Cool/Auto). |
| Léamh teochta míchruinn. | Suíomh an teirmeastait faoi thionchar dréachtaí, solas díreach na gréine, nó foinsí teasa. | Relocate thermostat if possible. Allow 15 minutes for sensor adjustment after installation or significant temperature changes. |
Sonraíochtaí
- Ainm an tSamhail: GC-TBZ48
- Uimhir Pháirt: BRO-NTBZ48
- Branda: GoControl
- Nascacht: Z-Wave (Ver. 4.5.5), Z-Wave FLiRS
- Foinse Cumhachta: 4 AA batteries (included) or 24V AC C-wire
- Cineál Taispeána: LCD with 7-character scrolling display
- Toisí: 9.59 x 6.16 x 2.08 orlach
- Meáchan Mír: 1.15 punt
- Ábhar: Plaisteach
- Dath: Bán
- Cineál Gléasta: Wall Mount or Single-Gang Junction Box
- Deimhnithe: UL Liostaithe
- Rialaitheoirí Comhoiriúnacha: Nexia, Vera, GoControl, Amazon Alexa (via compatible hub), SmartThings
Faisnéis Bharántas
The GoControl GC-TBZ48 Smart Thermostat comes with a Barántas 1 bhliain against manufacturer defects. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official GoControl documentation or contact customer support.
Tacaíocht do Chustaiméirí
For technical assistance, troubleshooting, or warranty inquiries, please contact GoControl customer support. Refer to the GoControl official websuíomh gréasáin le haghaidh an fhaisnéis teagmhála is déanaí.
Acmhainní Ar Líne:
- Official GoControl Website (for support contact and product information)
- Treoir Úsáideora (PDF): https://manuals.plus/m/9d31e8db4621f9c765178be18fb86e60397d995b2bbf0055524db570ec6b144d