Réamhrá
This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Carrier HK61EA005 OEM Replacement Furnace Control Board. Please read this manual thoroughly before proceeding with any installation or service procedures. Retain this manual for future reference.
Eolas Sábháilteachta
RABHADH: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment. Failure to follow these instructions could result in property damage, personal injury, or death.
- Dícheangail an chumhacht ón bhfoirnéis i gcónaí sula ndéantar an bord rialaithe a shuiteáil nó a sheirbhísiú.
- Verify all wiring connections are secure and correct according to the furnace manufacturer's specifications.
- Caith trealamh cosanta pearsanta (TCP) cuí, lena n-áirítear spéaclaí sábháilteachta agus lámhainní.
- Cinntigh go bhfuil córas na foirnéise ceangailte go ceart leis an talamh.
Táirge Tharview
The Carrier HK61EA005 is an OEM replacement furnace control board designed to manage the operational sequences of a furnace, including ignition, fan control, and safety monitoring. This board is compatible with various Carrier furnace models.

Fíor 1: Carrier HK61EA005 Furnace Control Board. This image displays the circuit board with various terminals, jumpers, and components. Key features include the "EASY SELECT" jumper settings for system type, ON/OFF DELAY settings, and terminal blocks for wiring connections such as D, R, W, W2, Y, Y2, G, O, and C. A yellow jumper wire is visible connecting two pins on the board.
Socrú agus Suiteáil
- Dícheangal Cumhachta: Múch an chumhacht leictreach go léir chuig an bhfoirnéis ag an bpríomhphainéal seirbhíse. Fíoraigh go bhfuil an chumhacht múchta ag baint úsáide as toirtmhéadar.tagméadar.
- Rochtain ar an Seanbhord: Oscail painéal rochtana an fhoirnéise chun an bord rialaithe atá ann cheana a aimsiú.
- Sreangú Doiciméad: Before disconnecting any wires, take clear photographs or make a detailed diagram of all wiring connections to the old control board. Note the position and color of each wire.
- Sreanga a Dhícheangal: Carefully disconnect all wires and connectors from the old control board.
- Bain an Sean-Bhord: Unmount the old control board from the furnace chassis. Note how it was secured (screws, clips, etc.).
- Suiteáil Bord Nua: Mount the new HK61EA005 control board in the same location and orientation as the old board. Ensure it is securely fastened.
- Ceangail Sreangú: Refer to your photographs or diagram and carefully reconnect all wires and connectors to the corresponding terminals on the new control board. Double-check each connection for accuracy and tightness.
- Socruithe Geansaí: Configure the "EASY SELECT" jumpers and ON/OFF DELAY jumpers on the new board to match the settings of the original board or the furnace manufacturer's specifications. These settings typically determine the system type (e.g., AC, HP) and fan delay times. Refer to the furnace wiring diagram for specific requirements.
- Dún an Painéal Rochtana: Once all connections are verified, close and secure the furnace access panel.
- Athchóirigh Cumhacht: Athchóirigh cumhacht leictreach don fhoirnéis ag an bpríomhphainéal seirbhíse.
Treoracha Oibriúcháin
After successful installation and power restoration, the furnace control board will initiate its normal operating sequence. The board manages the following functions:
- Seicheamh Adhaint: Controls the gas valve and igniter for safe furnace startup.
- Rialú Fan: Manages the indoor blower motor operation based on heating or cooling demands and delay settings.
- Monatóireacht Sábháilteachta: Continuously monitors various safety sensors (e.g., flame sensor, limit switches) and will shut down the furnace if a fault is detected.
- Comhéadan Teirmeastat: Communicates with the thermostat to receive heating and cooling calls.
For specific operational details, refer to your furnace's primary instruction manual.
Cothabháil
The HK61EA005 control board itself requires no routine maintenance. However, regular maintenance of the overall furnace system is crucial for its longevity and proper function. This includes:
- Athsholáthar Scagaire Aeir: Replace or clean the furnace air filter regularly (typically every 1-3 months) to ensure proper airflow.
- Cigireacht Ghairmiúil Bhliantúil: Have a qualified HVAC technician inspect and service your furnace annually.
- Clean Flame Sensor: A dirty flame sensor can cause intermittent furnace operation. This should be cleaned by a qualified technician.
Always disconnect power to the furnace before performing any maintenance.
Fabhtcheartú
If the furnace is not operating correctly after installing the new control board, consider the following troubleshooting steps:
- Gan Cumhacht:
- Check the circuit breaker for the furnace.
- Ensure the furnace disconnect switch is in the "ON" position.
- Fíoraigh gach íseal-toirttage agus ard-voltage connections to the control board are secure.
- Foirnéis Gan Lasadh:
- Confirm the thermostat is set to "HEAT" and the temperature is above the ambient room temperature.
- Check for error codes on the control board (if applicable, refer to your furnace manual for code interpretations).
- Déan cinnte go bhfuil an comhla soláthair gáis oscailte.
- Deimhnigh go bhfuil an braiteoir lasrach glan agus suite i gceart.
- Fan Not Operating Correctly:
- Check the "ON/OFF DELAY" jumper settings on the control board.
- Ensure the thermostat fan setting is correct (AUTO/ON).
- Verify the fan motor connections to the control board.
- Cóid Earráide: Many control boards have diagnostic LEDs that flash codes to indicate specific faults. Consult your furnace's original manual for a list of error codes and their meanings.
If troubleshooting steps do not resolve the issue, contact a qualified HVAC technician for assistance.
Sonraíochtaí
| Uimhir Mhúnla | HK61EA005 |
| Alternate Model Number | CECOMINOD058414 |
| Branda | Carrier (OEM Replacement) |
| Toisí Táirge | 6 x 6 x 6 orlach |
| Meáchan | 0.01 unsa |
| Dáta Ar Fáil den Chéad Uair | 8 Deireadh Fómhair, 2013 |
Barántas agus Tacaíocht
For warranty information regarding this OEM replacement part, please refer to the terms provided by your original point of purchase or the specific warranty documentation included with the product. For technical support, it is recommended to consult a qualified HVAC technician or the original furnace manufacturer's support resources.