1. Faisnéis Sábháilteachta
Before operating the KAIWEETS KE2500 Insulation Resistance Tester, please read and understand all safety warnings and operating instructions. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Cloí i gcónaí leis na cóid sábháilteachta áitiúla agus náisiúnta.
- This device is compliant with IEC/EN 61010-1 CAT III 1000V / CAT IV 600V safety standards.
- Ná húsáid an tástálaí má tá cuma damáiste air nó má tá na sreanga tástála i mbaol.
- Ensure the device is turned off and disconnected from any circuit before changing test leads or batteries.
- Wear appropriate personal protective equipment (PPE), including insulated gloves and safety glasses, when performing electrical tests.
- Avoid contact with live circuits. High voltages are present during insulation resistance testing.
- Do not operate the tester in wet conditions or in the presence of explosive gases or dust.
- Keep hands and fingers behind the probe barriers during testing.
2. Táirge Tharview
The KAIWEETS KE2500 is a professional digital insulation resistance tester designed for precise measurements in various electrical maintenance and safety verification tasks. It offers a wide range of test voltages and advanced diagnostic capabilities.
Príomhghnéithe:
- 5-Range Insulation Testing: 100V, 250V, 500V, 1000V, 2500V DC.
- Wide Resistance Range: 0.1MΩ to 200GΩ.
- Ard-Dhiagnóisic: One-touch Absorption Ratio (DAR) and Polarization Index (PI) calculation.
- Intelligent PASS/FAIL Evaluation: Customizable thresholds for quick quality control.
- Ilfheidhmeacht: Bearta AC/DC Imltage (up to 750V AC / 1000V DC) and Continuity (buzzer for <50Ω).
- Dearadh cairdiúil: Backlit LCD, Data Hold, 15-minute Auto Shutdown, Max/Min recording.
Cad atá san áireamh:
- KAIWEETS KE2500 Insulation Tester (x1)
- 1.5V AA Batteries (x8)
- Test Leads (x2)
- Crocodile Alligator Clips (x2)
- Carrying Bag (x1)
- Lámhleabhar Úsáideora (x1)

Image: KAIWEETS KE2500 Insulation Resistance Tester and included accessories.
Físeán: Thar barrview of the KAIWEETS Professional Insulation Resistance Tester KE2500, demonstrating its features and use.
3. Socrú
Suiteáil Battery:
- Ensure the tester is powered off.
- Aimsigh an urrann ceallraí ar chúl an ghléis.
- Oscail an clúdach urrann ceallraí.
- Insert 8 AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Dún an clúdach urrann ceallraí go daingean.

Image: The KAIWEETS KE2500 with its battery compartment open, showing the placement for 8 AA batteries.
Ceangal Luaidhe Tástála:
- Connect the red test lead to the 'LINE' terminal and the black test lead to the 'EARTH' terminal for insulation resistance tests.
- Le haghaidh voltage measurements, connect the red test lead to the 'V' terminal and the black test lead to the 'G' (Ground) terminal.
- For continuity tests, connect the red test lead to the 'CONTINUITY' terminal and the black test lead to the 'G' (Ground) terminal.
- Attach the alligator clips to the test leads as needed for secure connections.

Image: Close-up of the KAIWEETS KE2500 showing the input terminals for test leads, labeled LINE, V, G, EARTH, and CONTINUITY.
4. Treoracha Oibriúcháin
Cumhachtú Ar/As:
Rotate the central dial from 'OFF' to any desired measurement function to power on the device. Rotate back to 'OFF' to power off. The device also features a 15-minute auto-shutdown to conserve battery life.
Tástáil Friotaíocht Inslithe:
- Ensure the test leads are correctly connected to the 'LINE' and 'EARTH' terminals.
- Rotate the dial to select the desired test voltage (100V, 250V, 500V, 1000V, nó 2500V).
- Ceangail na sreanga tástála leis an gciorcad nó leis an gcomhpháirt atá faoi thástáil.
- Press the 'TEST' button to initiate the insulation resistance measurement. The display will show the resistance value.
- Release the 'TEST' button to stop the measurement.

Image: The KE2500 displaying an insulation resistance measurement, showing the range up to 200GΩ.
Timed Measurement Function:
- After selecting the test voltage, press the 'TIMER' button.
- Use the 'HOLD' and 'MAX/MIN' buttons to adjust the desired test duration (e.g., 1 minute, 5 minutes).
- Press 'TEST' to start the timed measurement. The device will automatically stop after the set time.

Image: The KE2500 displaying a timed insulation resistance test, showing the elapsed time.
DAR/PI Calculation:
The Absorption Ratio (DAR) and Polarization Index (PI) are indicators of insulation quality. The KE2500 can calculate these automatically.
- Perform an insulation resistance test as described above.
- Press the 'DAR/PI' button. The device will display the calculated DAR or PI value.
- DAR is calculated as the ratio of 60-second insulation resistance to 15-second insulation resistance.
- PI is calculated as the ratio of 10-minute insulation resistance to 1-minute insulation resistance.

Image: The KE2500 showing the DAR/PI calculation function, indicating the ratio of resistance measurements over time.
Threshold Comparison (PASS/FAIL):
- Press the 'COMP' button to enter comparison mode.
- Use the 'HOLD' and 'MAX/MIN' buttons to set your desired insulation resistance threshold.
- Perform an insulation resistance test. The display will indicate 'PASS' or 'FAIL' based on your set threshold.

Image: The KE2500 displaying a PASS/FAIL result based on a user-defined threshold for insulation resistance.
AC / DC Voltage Tomhas:
- Connect the test leads to the 'V' and 'G' terminals.
- Rotate the dial to the 'AC/DC-V' position.
- Connect the test probes to the circuit to measure AC or DC voltage. The device automatically detects AC or DC.

Image: The KE2500 measuring AC voltage in an electrical panel, showing the display with AC voltage ag léamh.

Image: The KE2500 measuring DC voltage on a car battery, showing the display with DC voltage ag léamh.
Tástáil Leanúnachais:
- Connect the test leads to the 'CONTINUITY' and 'G' terminals.
- Rotate the dial to the 'Ω' position.
- Connect the test probes to the circuit or component. A buzzer will sound if the resistance is less than 50Ω.

Image: The KE2500 performing a continuity test, showing the display with a low resistance reading and indicating continuity.
Data Hold, Max/Min, and Backlight:
- Press 'HOLD' to freeze the current reading on the display. Press again to release.
- Press 'MAX/MIN' to cycle through maximum, minimum, and average readings during a measurement session.
- Press the backlight button (often combined with 'HOLD' or a separate button) to illuminate the LCD for low-light conditions.

Image: The KE2500 with its backlit LCD display illuminated, showing clear visibility of readings.
5. Cothabháil
Glanadh:
Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure the device is off and disconnected from any power source before cleaning.
Athsholáthar Ceallra:
When the low battery indicator appears on the display, replace all 8 AA batteries promptly to ensure accurate readings and proper operation. Refer to the 'Battery Installation' section for detailed steps.
Stóráil:
Store the tester in its carrying bag in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
6. Fabhtcheartú
- Gan Taispeántas/Cumhacht Ar Siúl: Seiceáil suiteáil na gceallraí agus cinntigh nach bhfuil na ceallraí ídithe. Athraigh iad más gá.
- Léamha Míchruinn: Ensure test leads are securely connected and not damaged. Verify the correct measurement function and voltage range are selected. Clean the test probes if they are dirty.
- Taispeántas 'OL' (Ró-ualaigh): This indicates the measured value is outside the device's range. For insulation resistance, it means the resistance is too high to measure. For voltage, it means the voltage exceeds the maximum input.
- No Continuity Buzzer: Ensure the device is in continuity mode and the resistance is below 50Ω. Check test leads for proper connection.
7. Sonraíochtaí
| Sonraíocht | Luach |
|---|---|
| Branda | KAIWEETS |
| Uimhir Mhúnla | KE2500 |
| Foinse Cumhachta | 8 Cadhnra AA (san áireamh) |
| Raon Friotaíocht Inslithe | 0.1MΩ to 200GΩ |
| DC Test Voltages | 100V, 250V, 500V, 1000V, 2500V |
| AC Voltage Tomhas | Suas le 750V AC |
| DC Imltage Tomhas | Suas go dtí 1000V DC |
| Bazzer Leanúnachais | <50Ω |
| Rátáil Sábháilteachta | IEC/EN 61010-1 CAT III 1000V / CAT IV 600V |
| Múchadh Uathoibríoch | 15 nóiméad |
| Meáchan Mír | 3.53 punt (1600 gram) |
| Toisí Táirge | 11.81 x 9.06 x 2.76 orlach |
8. Barántas agus Tacaíocht
KAIWEETS provides a 36-month after-sales service for the KE2500 Insulation Resistance Tester. For any technical assistance or inquiries, please contact KAIWEETS customer support. Round-the-clock lifetime technical support is available to ensure your satisfaction and proper use of the product.
For further information or support, please visit the official KAIWEETS websuíomh nó déan teagmháil dhíreach lena seirbhís do chustaiméirí.