TRACEABLE Excursion-Trac
Lámhleabhar Úsáideora Teirmiméadar Logálaí Sonraí Inrianaithe Excursion-Trac
Model: Excursion-Trac
Réamhrá
The Traceable Excursion-Trac Data Logger Thermometer is designed for precise temperature monitoring and data recording. This device simultaneously displays current, minimum, and maximum temperatures, and features a rolling memory for extensive data storage. It is equipped with a submersible probe and offers customizable alarm functions to ensure critical temperature conditions are maintained and recorded.

Image: The Traceable Excursion-Trac Data Logger Thermometer, showing its digital display and connected bullet probe.
Ábhar an Phacáiste
Deimhnigh go bhfuil na hearraí go léir i láthair nuair a dhíphacáiltear iad:
- Traceable Excursion-Trac Data Logger Thermometer Unit
- Bullet Probe with 10-ft (3-m) Cable
- Tiomántán USB flash
- Flip-Open Stand
- Hook-and-Loop Strips
- Magnetic Strips
- Wall-Mount Receptacle
- Batteries (pre-installed or separate)
- NIST-Traceable Calibration Certificate with Data
Socrú
- Suiteáil Battery: If batteries are not pre-installed, open the battery compartment on the back of the unit and insert the specified batteries, observing correct polarity.
- Ceangal Taiscéalaí: Connect the bullet probe cable to the designated port on the thermometer unit. Ensure a secure connection.
- Socrúchán Tosaigh: Position the thermometer unit using the flip-open stand for a benchtop, or utilize the hook-and-loop strips, magnetic strips, or wall-mount receptacle for secure placement. The 10-ft (3-m) submersible micro-cable allows the probe to be placed in the desired monitoring location, even permitting doors to close over the cable.
- Cumhacht ar: Press the power button (if available) or ensure the unit is active. The display should illuminate, showing current temperature readings.
Treoracha Oibriúcháin
Oibríocht Bhunúsach
- Taispeáin: The LCD simultaneously shows the current temperature, minimum recorded temperature (MIN), and maximum recorded temperature (MAX).
- Aonaid: Use the 'UNITS' button to toggle between Celsius (°C) and Fahrenheit (°F) temperature scales.
- Cuimhne View: The 'MEM VIEW' function allows review of stored data.
Logáil Sonraí
- The device features rolling memory, capable of retaining the most recent 525,600 temperature observations.
- Aistriú Sonraí: To transfer recorded data, insert the provided USB flash drive into the unit's USB port. The data will be saved as a CSV file, accessible on any computer without special software.
- Glan Cuimhne: After downloading data and alarm events, the memory can be cleared to continue recording new data. Refer to the device's specific buttons (e.g., 'CLEAR') for this function.
Feidhmeanna Aláraim
- The thermometer allows setting limits for and storing up to 10 unique alarm events.
- Aláraim a Shocrú: Use the 'ALARM' and 'SELECT/ADVANCE' buttons to set desired high and low temperature alarm thresholds.
- Smart-Alarm Function: The Smart-Alarm provides both visual and audible alerts. It continues to alert even if conditions return to the normal temperature range, ensuring that any excursion is noted.
- Aláram Tost: An 'ALARM SILENCE' button is available to temporarily mute audible alerts.
Cothabháil
- Glanadh: Glan an t-aonad le fógraamp cloth. Do not submerge the main unit in water. The bullet probe is submersible and can be cleaned as needed.
- Athsholáthar Ceallra: When the battery indicator appears or the unit fails to power on, replace the batteries. Refer to the battery compartment for the correct battery type.
- Probe Care: Handle the probe and its cable with care to prevent damage. Avoid sharp bends or excessive pulling on the cable.
Fabhtcheartú
| Eisiúint | Cúis Féideartha | Réiteach |
|---|---|---|
| Unit does not power on or display is blank. | Cadhnraí marbh nó suiteáilte go míchuí. | Cuir na cadhnraí ina n-áit, agus cinntigh go bhfuil an polaraíocht cheart. |
| Léamha teochta míchruinn. | Probe not properly connected or damaged. | Ensure probe is securely connected. Inspect probe and cable for visible damage. |
| Data not transferring to USB drive. | USB drive not properly inserted or full. | Re-insert USB drive. Ensure the drive has sufficient space. Try a different USB drive if available. |
| Alarm not sounding or not clearing. | Alarm settings incorrect or alarm silenced. | Verify alarm thresholds. Check if the alarm has been manually silenced. |
Sonraíochtaí
| Gné | Sonraigh |
|---|---|
| Uimhir Mhúnla | Excursion-Trac |
| Raon Teochta | –58 to 158 Degrees Fahrenheit (-50 to 70 Degrees Celsius) |
| Rún | 0.01 Céim |
| Cruinneas | 0.25 Céim Celsius |
| Cumas Logála Sonraí | 525,600 temperature observations (rolling memory) |
| Nascacht | USB (for CSV data transfer) |
| Cineál Taispeána | LCD |
| Gné Speisialta | Alarm (Smart-Alarm function) |
| Cineál Tóraigh | Bullet Probe, Submersible, 10-ft (3-m) cable |
| Ábhar | Plaisteach |
| Cúram Táirge | Wipe Glan |
| Deimhniú | Calabrú NIST-inrianaithe |